HI96802 Digital Refractometer for % Fructose by Weight Analysis
HI96802 Digital Refractometer for % Fructose by Weight Analysis Sugar Analysis Refractometers Selangor, Malaysia, Penang, Sabah, Kuala Lumpur (KL), Petaling Jaya (PJ), Sungai Nibong, Kota Kinabalu Supplier, Suppliers, Supply, Supplies | Hanna Instruments (M) Sdn Bhd
RM 1,315.00
500 g
1 in stock
Hanna Lab - Learn About the Hanna Instruments Fructose Refractometer HI96802

Download Files
HI96802.pdf (465.68 KB)
The HI96802 is a rugged, portable digital refractometer for food products is designed to report the content of aqueous solutions containing sugar as % fructose by weight (%w/w). The HI96802 report the results with an accuracy of ±0.2%. The operation of the meter is simplified with only two buttons: one button is to calibrate with distilled or deionized water and the other to take a measurement. All readings are automatically compensated for temperature variations according to the ICUMSA Methods Book standard and displayed with a 1.5 second response time. The sealed flint glass prism and stainless steel well are easy to clean. Just wipe with a soft cloth in preparation for the next sample.
 
  • Sample size as small as 2 metric drops (100 μl)
  • Sealed stainless steel well with high grade optical prism made of flint glass
  • Fast 1.5 second response time for temperature compensated readings

Details

The HI96802 Digital Fructose Refractometer converts the refractive index of a food sample to % fructose by weight. This conversion is based on the tables found in the ICUMSA Methods Book (International Commission for Uniform Methods of Sugar Analysis) that documents the changes in refractive index with temperature for a percent by weight fructose solution. The HI96802 is ideal for the analysis of fruits, energy drinks, puddings, soy milk, juices, jam, marmalade, honey, soups, jelly, tofu and condiments. The HI96802 is an easy to use tool for measuring sugar in food samples in the field or in the lab.

  • Designed for food sugar analysis
  • Temperature Compensation algorithms based on fructose solution
  • 0 to 85% fructose by weight range with an accuracy of ± 0.2%

Making a Standard % Sucrose Solution

To make a Fructose Solution, follow the procedure below:

  • Place container (such as a glass vial or dropper bottle that has a cover) on an analytical balance.
  • Tare the balance.
  • Weigh out X grams of high purity fructose (CAS #: 57-48-7) directly into a beaker
  • Add distilled or deionized water to the beaker so the total weight of the solution is 100g.
  • Note: Solutions above 65% may need to be vigorously stirred or shaken and heated in a water bath to roughly 40°C (104°F). Remove solution when fructose has dissolved and allow to cool before use.

Example to prepare as 25% fructose solution:

Fructose % (g/100g) Fructose (g) Water (g) Total (g)
25 25.000 75.000 100.000
 
refractive index

Refractive Index

The HI96802 takes measurements based on a sample’s refractive index. Refractive index is a measurement of how light behaves as it passes through the sample. Depending on the sample’s composition, light will refract and reflect differently. By measuring this activity with a linear image sensor, the sample’s refractive index can be assessed and used to determine its physical properties such as concentration and density. In addition to the linear image sensor, the HI96802 uses an LED light, prism and lens to make measurement possible.

Variations in temperature will affect the density of a solution based on the compound that is present. In digital refractometry the use of temperature compensation is necessary for accurate results. The HI96802 contains a built-in temperature sensor and is programmed with temperature compensation algorithms in accordance with the ICUMSA Methods Book for a percent by weight fructose solution.

 

Features at-a-glance:

 
One-point calibration
  • Calibrate with distilled or deionized water

Small sample size
  • Sample size can be as small as 2 metric drops (100 μl)

Automatic Temperature Compensation (ATC)
  • Samples automatically compensated for temperature variations

Quick, accurate results
  • Readings are displayed in approximately 1.5 seconds

Dual-level LCD
  • The dual-level LCD displays % Brix and temperature readings simultaneously
Stainless steel sample well
  • Easy to clean and corrosion-resistant

Battery indicators
  • Battery percent level remaining at startup and low battery indicator

Automatic shut-off
  • To conserve battery life the meter shuts off automatically after three minutes of non-use

IP65 water resistant protection
  • Water resistant ABS plastic casing designed to perform under laboratory and field conditions.

Specifications
 
Sugar Content Range 0 to 85% mass (% w/w fructose)
Sugar Content Resolution 0.1% mass
Sugar Content Accuracy (@25ºC/77ºF) ±0.2% mass
Temperature Range 0 to 80°C (32 to 176°F)
Temperature Resolution 0.1°C (0.1°F)
Temperature Accuracy ±0.3 °C (±0.5 °F)
Temperature Compensation automatic between 10 and 40°C (50 to 104°F)
Measurement Time approximately 1.5 seconds
Minimum Sample Volume 100 μL (to cover prism totally)
Light Source yellow LED
Sample Cell stainless steel ring and flint glass prism
Auto-off after three minutes of inactivity
Enclosure Rating IP65
Battery Type / Life 9V / approximately 5000 readings
Dimensions / Weight 192 x 102 x 67 mm (7.6 x 4.01 x 2.6”) / 420 g (14.8 oz.)
Ordering Information HI96802 is supplied with battery and instruction manual

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf
Switch To Desktop Version