HI84502-55 Pump Calibration Standard for Titratable Acidity in Wine Mini Titrator
HI84502-55 Pump Calibration Standard for Titratable Acidity in Wine Mini Titrator Titration Solutions Solutions Selangor, Malaysia, Penang, Sabah, Kuala Lumpur (KL), Petaling Jaya (PJ), Sungai Nibong, Kota Kinabalu Supplier, Suppliers, Supply, Supplies | Hanna Instruments (M) Sdn Bhd
RM 210.00
300 g
1 in stock
Download Files
us_hi84502_55_ghs_usa_1.pdf (343.28 KB)
The HI84502-55 is a 120 mL bottle of pump calibration standard that is used to calibrate the dosing system of the HI84502 TItratable Acidity Mini Titrator for Wine Analysis. With 4 mL of solution required per pump calibration, there is enough standard to perform approximately 30 pump calibrations.

 

A calibrated dosing pump allows for the accurate determination of the amount of titrant used when performing a titration. The amount of volume dosed along with the concentration of the titrant is used by the pre-programmed formula within the HI84502 in determining the exact titratable acidity. The pump calibration procedure should be performed anytime the titrant or pH electrode is replaced. Routine calibration is recommended to ensure the highest of accuracy when performing a titration.
  • Pre-measured solution
  • Clearly marked expiration date and lot number
  • Air tight bottle with tamper-proof seal











Details

Analysis of titratable acidity in wine, as performed on the HI84502 mini titrator, utilizes a simple sample preparation, a high quality titrant dosing pump, potentiometric endpoint detector, and automatic computations. As the titrant comes pre-standardized, it is important to determine the amount of titrant delivered by the dosing pump by performing a pump calibration procedure. In this procedure, the analysis of a known volume of a known solution is titrated with to the pH 8.2 endpoint determined by the HI1048B pH electrode. The same pump calibration solution is used for both the low and high ranges. The pump calibration procedure should be performed anytime the titrant, syringe, tubing or pH electrode is replaced. It is recommended to do a pump calibration every time a new set of titrations are to be performed.

Replacement reagents required to operate the HI84502 include:

 

Low Range - 0.1 to 5.0 g/L of tartaric acid

High Range - 4.0 to 25.0 g/L of tartaric acid

Pump calibration standard

HI84502-55

Titrant solution

HI84502-50

 

Specifications

Package bottles
Size 120 mL
Quantity 1