HI5312 Reference Electrode for Samples with Suspended Solids
HI5312 Reference Electrode for Samples with Suspended Solids Ph Electrodes & Probes Selangor, Malaysia, Penang, Sabah, Kuala Lumpur (KL), Petaling Jaya (PJ), Sungai Nibong, Kota Kinabalu Supplier, Suppliers, Supply, Supplies | Hanna Instruments (M) Sdn Bhd FC260B Foodcare pH Half-Cell Electrode with BNC Connector HI3133B Platinum ORP Half-Cell Electrode with BNC Connector HI70300L Electrode Storage Solution (500 mL) HI7061L General Purpose Cleaning Solution (500 mL) HI7010L pH 10.01 Calibration Solution (500 mL) HI7007L pH 7.01 Calibration Solution (500 mL) HI7004L pH 4.01 Calibration Solution (500 mL)
RM 873.00
500 g
1 in stock
The HI5312 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a PTFE sleeve junction in the outer reference cell and is made for use in temperatures ranging from -5 to 80°C.

 

This design consideration is made for measurements in samples with suspended solids, and can also be used in a variety of titrations.

  • Half-Cell Design
  • Refillable Electrode
  • PTFE Sleeve Junction

Details

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI5312 uses a glass body, PTFE sleeve junction and is refillable with 3.5M KCl.

glass electrode body

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium the steadier the reference potential.

 

sleeve junction

PTFE Sleeve Junction

Conventional pH electrodes use ceramic junctions that clog quickly when used in samples with high amounts of particulates. When the junction is clogged, the electrode does not function. The use of a polytetrafluoroethylene (PTFE) sleeve junction prevents clogging of the junction and allows proper flow of the liquid electrolyte. As a result, pH electrodes with sleeve junctions stay fresh up to 20 times longer than conventional electrodes.

 

Refillable

Refillable

The HI5312 is a refillable reference electrode. Since it is a double junction electrode the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode. The absence of silver will prevent any silver precipitate from forming at the junction surface and clogging it. Clogging of the junction will result in drifty and erratic readings.

 

Banana pin connector

4 mm Connector

The HI5312 uses a 4 mm banana connector. This type of connector is easily plugged into the reference input on suitable meters. Other type of connectors include BNC, DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.

 

half cell electrode

 

Specifications

Body Material glass
Reference double, Ag/AgCl
Junction / Flow Rate PTFE
Electrolyte 3.5M KCl
Max Pressure 0.1 bar
Diameter 10 mm
Body Length / Overall Length 120 mm / 175.5 mm
Recommended Operating Temperature -5 to 80°C (23 to 176°F)
Cable 1 m (3.3')
Connection banana
Applications samples with suspended solids, titrations