HI8077L Cleaning Solution for Oil and Fats in FDA Bottle (500 mL)
HI8077L Cleaning Solution for Oil and Fats in FDA Bottle (500 mL) Cleaning Solutions Solutions Selangor, Malaysia, Penang, Sabah, Kuala Lumpur (KL), Petaling Jaya (PJ), Sungai Nibong, Kota Kinabalu Supplier, Suppliers, Supply, Supplies | Hanna Instruments (M) Sdn Bhd
RM 176.00
1.000 KG
0 in stock
Download Files
us_hi8077_ghs_usa_1.pdf (280.18 KB)
The HI8077L is a neutral, effective cleaning solution that comes in an FDA compliant bottle. It is specially formulated for use in applications that permit electrodes to come into contact with oil and fats. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.

  • Specially formulated cleaning solution to remove oil and fats from a pH electrode
  • Air tight seal to ensure quality and efficiency is maintained
  • Light blocking FDA compliant bottle

Details

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.

 

The Cleaning Solution Series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The HI8077L is a cleaning solution made specifically for applications that involve the measurement of pH in a oil or fats based solution.

FDA compliant bottle

  • Light blocking bottle to prevent against degradation by UV light

 

Air tight bottle with tamper-proof seal

  • Ensures quality and freshness of solution

 

Each bottle marked with lot number and expiration date.

  • Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.

Hanna offers a complete line of cleaning solutions engineered for specific applications.

Specifications

Application Oil and Fats
Package bottles
Size 500 mL
Quantity 1
FDA Compliant Bottle Yes
Certificate of Analysis No





The Cleaning Solution Series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The HI8077L is a cleaning solution made specifically for applications that involve the measurement of pH in a oil or fats based solution.

Please leave your enquiry here, we will reply as soon as possible.


*only support gif, jpeg, jpg, png, pdf
Switch To Desktop Version